We are always looking to improve your electron microscopy experience, whether through enhanced access to service experts, easy to use step-by-step guides, or hands-on training. We also know your electron microscopy lab requires maintenance to stay in top shape. A critical component of this ecosystem is powerful software that enables you to get the best results possible from your instrumentation. That is why we offer a constant stream of improvements and updates to our software, ensuring you are able to achieve your goals as quickly and easily as possible.
Be the first to know the latest software updates
Comments on this content can be mailed to UpdateEM.
Release notes
Description of updates
Contact the service team for a full upgrade of Athena Software. Some features may require additional packages.
Description of updates
Contact the service team for a full upgrade of Athena Software. Some features may require additional packages.
Description of updates
Contact the service team for a full upgrade of Athena Software. Some features may require additional packages.
Description of updates
Discovery Viewer can be used in two ways: from high- to low-magnification images or vice versa.
Clicking on the CTF card displays the CTF view, where users can quickly visualize the CTF fit for all slices of the tilt-series.
Contact the service team for a full upgrade of Athena Software. Some features may require additional packages.
A new workflow, “Single particle analysis with CryoSPARC Live,” is available. Every EPU Run created in this workflow will create a new Embedded CryoSPARC Live session in which the acquired micrograph will be automatically processed.
The Embedded CryoSPARC Live interface can be directly accessed from Athena Software to simplify navigation. Processing results of Embedded CryoSPARC Live are automatically registered into Athena Software to enable Smart EPU Software with Embedded CryoSPARC Live. The export panel provides the path where that data will be exported.
Contact the service team for a full upgrade of Athena Software. Some features may require additional packages.
Description of updates
Applicable instruments
Description of updates
Description of updates
Description of updates
Description of updates
Description of updates
Description of updates
Watch this tutorial to learn how recently released features can facilitate sample screening.
Compatibility: Titan SW 3.13.x – 3.18.x / Talos SW: 2.13.x – 2.18.x.
For questions, please contact EPU@Thermofisher.com
Description of updates
Watch this tutorial to learn how recently released features can facilitate sample screening.
Compatibility: Titan Cryo-TEM SW 3.12.x – 3.17.x / Talos TEM SW: 2.12.x – 2.17.x.
For questions, please contact EPU@Thermofisher.com
Description of updates
Watch this tutorial to learn how recently released features can facilitate sample screening.
Note: You can upgrade to EPU Software 3.x if you have a valid EPU license. If you have Smart EPU Software, please contact service for a combined EPU and Athena Software update. Updating only EPU Software might break compatibility with processing and smart automation features.
Compatibility: Titan SW 3.11.x – 3.16.x / Talos SW: 2.11.x – 2.16.x.
For questions, please contact EPU@Thermofisher.com
Description of updates
Watch this tutorial to learn how to use Discovery Viewer to identify grid areas for high-quality data acquisition.
Note: You can upgrade to EPU 3.x if you have a valid EPU license. If you have Smart EPU please contact service for a combined EPU and Athena software update. Updating only EPU might brake compatibility with processing and smart automation features.
Compatibility: Titan SW 3.10.x – 3.15.x / Talos SW: 2.10.x – 2.15.x.
For questions, please contact EPU@Thermofisher.com
Description of updates
To obtain update: Download here
Note: You can upgrade to EPU 3.x if you have a valid EPU license. Some of the Smart EPU features will need a full upgrade of Athena performed by service and depend on the existence of certain additional packages.
Description of updates
To obtain update: Download here
Note: You can upgrade to EPU 3.x if you have a valid EPU license. Some of the Smart EPU features will need a full upgrade of Athena performed by service and depend on the existence of certain additional packages.
*Multigrid availability:
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Description of updates
Description of updates
Description of updates
The EPU-D 1.15 release does not introduce new features or major improvements. It maintains compatibility with new Titan and Talos TEM software versions.
Description of updates
Description of updates
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
When the OptiSTEM autofunction fails to converge, or when the quality of the result is poor, the Maps Software application automatically restores the focus and stigmator values to the last known good state.
Maps Software now supports the latest TEM server versions for Titan (TEM 3.17) and Talos (TEM 2.17) TEMs.
Description of updates
The “Center View on Sample,” “Center View on Selection,” and “Go to Microscope FOV” viewer functions in the toolbar now animate pan and zoom to help keep you oriented in the sample space. If desired, you can deactivate this feature under the “Animate Pan & Zoom” View menu item.
Slit insertion state and energy-selecting slit width can now be set directly on a tile set. Slit parameters are also now part of EFTEM tile set templates and are propagated from Tomography Software presets when importing the presets to Maps Software.
The Project History window now has a search bar available. When you use this search bar, it immediately filters the project history and provides results that match either the Project Name or Project Description fields.
TEM and EFTEM autofunctions support a new setting called "Use Image Filtering". You can use this new setting to improve the reliability and accuracy of these autofunctions.
Maps Software now supports the latest TEM server versions for the Titan Cryo-TEM (TEM 3.16) and Talos TEM (TEM 2.16).
Description of updates
Maps Software now supports the latest TEM server versions for Titan TEM 3.15 and Talos TEM 2.15.
The integration between Maps Software and Tomography Software has been enhanced to support cryo-ET scenarios. The following data can now be automatically synchronized between both applications:
The OptiSTEM autofunction has been added to the list of supported autofunctions on STEM as a beta feature. This autofunction corrects defocus and condenser astigmatism (A1/C1). It requires Thermo Scientific Sherpa Software with the OptiSTEM license to be installed on the system. This feature is only available on 2.15 and 3.15 TEM Server versions.
Previously, temporary data created by Maps Software on TEM was stored on the system drive (C:). The default location has been changed to the data drive (D:) to provide more effective management of free space and backups on the system drive. The data written to D: drive includes EDS maps from Velox Software and intermediate images produced during acquisition (that is, when image logging is activated).
Description of updates
Maps Software no longer presents the end user license agreement during the application installation process. Instead, it now prompts you to read the end user license agreement immediately after you launch the application.
Applicable instruments
Description of updates
Contact our on-site software service for update
Description of updates
Description of updates
Description of updates
Description of updates
Description of updates
To obtain update: Download here
Description of updates
To obtain update: Download here
Description of updates
The Biprisms tool is available in the Microscope Software Launcher > Tools > Optics menu.
Multiple improvements and new functionalities to enable more and better user assistance via the Traffic Light that is available in front-end applications, such as EPU, Tomography, and MiCo Software.
The new Falcon C Detector is supported by the AFIS calibration and by the Optimize Optics SPA sequence.
The sample count is no longer included in the criteria for the CryoCycle recommendation.
To obtain update: Contact our On-Site software update service
Description of updates
The minimum dwell-time is restricted to the fastest rate at which no frames will be dropped.
The recommended Cryo Cycle intervals are updated:
As of TEM Server 7.16.1, the N2(g) pressure is no longer checked to determine the status of the CLS. If the N2(g) pressure is not OK, then the status of the CLS can still be OK. An incorrect N2(g) pressure does not block normal operation of the CLS.
To obtain update: Contact our On-Site software update service
Description of updates
For these improvements, the new BeamCurrentControl calibration must be performed by a Thermo Fisher Scientific engineer.
When the system is in STEM mode, the Electron Dose Control (EDC) functionality:
Conditions and restrictions:
The STEM Mh Mode option is now available on all Titan TEM systems with STEM.
On Spectra S/TEM systems, Lorentz Mode (STEM) is available.
The homing procedure is improved. Before any axis is moved, all axes are checked for error states.
When one or more axes are in an error state, the homing procedure will first attempt recover the error. If recovery fails, the homing procedure will not start.
In preceding software releases the homing procedure would always start and would fail when an axis could not be homed.
If a displayed tooltip mentions a condition, the tooltip is updated immediately according to the changed condition.
For BSL3 compliant systems, the OSD is automatically shut down when a decontamination heating procedure starts.
The homing procedure is improved. Before any axis is moved, all axes are checked for error states.
When one or more axes are in an error state, the homing procedure will first attempt recover the error. If recovery fails, the homing procedure will not start.
In preceding software releases the homing procedure would always start and would fail when an axis could not be homed.
Dual-X detectors are now supported on Talos F200i TEM with a C-Twin lens.
The Beam Diameter as displayed in Tomography on Titan TEM systems is now also available on:
The accuracy of the calculated Beam Diameter is typically ±20%, but this depends on the accuracy of the Focus and Stigmate alignment and on the selected Spot Size.
If a displayed tooltip mentions a condition, then the tooltip is updated immediately according to the changed condition.
For BSL3 compliant systems, the OSD is automatically shut down when a decontamination heating procedure starts.
The homing procedure is improved. Before any axis is moved, all axes are checked for error states. When one or more axes are in an error state, the homing procedure will first attempt recover the error. If recovery fails, the homing procedure will not start.
In preceding software releases the homing procedure would always start and would fail when an axis could not be homed.
Align Genie is no longer available in Sherpa. The functionality that was offered via Align Genie is now available in MiCo.
In SALSA > Transfer Device, an Exchange widget is available for each attached Transfer Device (TD). In this widget, the new Write data function writes the rough transfer position to the TD.
The TEM User Interface can no longer be started by a regular user. Regular users should use MiCo. To gain access to the TEM User Interface, request a supervisor or a Thermo Fisher Scientific engineer to open the Microscope Software Launcher > Tools > Microscope UI Access Provider, enter their credentials and select Provide Access.
To obtain update: Contact our On-Site software update service
Description of updates
Improved robustness of the beam detection and ellipse fitting algorithms.
High End TEMs:
Mid-Range TEM:
Entry Level TEM:
To obtain update: Contact our On-Site software update service
High End TEMs:
Mid-Range TEM:
Entry Level TEM:
To obtain update: Contact our On-Site software update service
Source and HT:
Vacuum:
Optics:
Cameras, filters, and detectors:
Motion and Sample Loaders:
All items below are applicable for Tundra systems:
Contact our on-site software service for update
Contact our on-site software service for update
Contact our on-site software service for update
Applicable instruments
Description of updates
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Description of updates: 2.15.1, 2.15.2
Applicable instruments
Contact our on-site software service for update
Contact our on-site software service for update
Applicable instruments
Contact our on-site software service for update
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Applicable instruments
Description of updates
Compatibility: Titan SW 3.13.x – 3.18.x / Talos SW: 2.13.x – 2.18.x.
Description of updates
Compatibility: Titan Cryo-TEM SW 3.12.x – 3.17.x / Talos TEM SW: 2.12.x – 2.17.x.
Description of updates
Compatibility: Titan TEM SW 3.11.x – 3.16.x / Talos TEM SW: 2.11.x – 2.16.x.
Description of updates
Compatibility: Titan SW 3.10.x – 3.15.x / Talos SW: 2.10.x – 2.15.x.
Description of updates
To obtain update: Download here
Description of updates
To obtain update: Download here
Applicable instruments
Free of charge for service contracts
Applicable instruments
Included in service contracts
Applicable instruments
For first-time installations, a 90-day Trial License is available to evaluate the software
Applicable instruments
Free of charge for service contracts
Applicable instruments
Tomography > Automated Acquisition:
No license is required to upgrade from Tomo 4.x to 5.x
Applicable instruments
No license update is required to upgrade from Tomo 4.x to 5.x
Applicable instruments
Free of charge for service contracts
Description of updates
Compatibility: Titan SW 3.13.x – 3.18.x / Talos SW: 2.13.x – 2.18.x.
For more details please visit here
Description of updates
Compatibility: Titan Cryo-TEM SW 3.12.x – 3.17.x / Talos TEM SW: 2.12.x – 2.17.x.
For more details please visit here
Description of updates
For more information please visit the Velox Software page
Description of updates
The dose can now be set and edited from the Velox Acquisition settings panel. It will change the beam current to achieve the desired dose. Moving the mouse over a STEM image in Velox will display the Dose Per Pixel (requires Panther STEM detector-
Description of updates
To obtain update: Download here
Description of updates
To obtain update: Download here
Description of updates
Description of updates
Applicable instruments
Description of updates
Applicable instruments
Free of charge for service contracts
Applicable instruments
Description of updates
Applicable instruments
Description of updates
Applicable instruments
Description of updates
Free of charge for service contracts
MRC-2014 Specifications
(25 September 2020)
Thermo Scientific microscopy applications use the MRC2014 data format to store, view, and process images. This document specifies:
EER-2023 Specifications
(July 2023)
Some cameras can produce EER encoded images. These images are stored in a file format called the EER file format, identified by the extension “.eer”. EER files are based on BigTIFF, but define a number of extensions to this format to store all EER-related information in one file. This document describes the currently implemented file format.
To ensure optimal system performance, we provide you access to a world-class network of field service experts, technical support, and certified spare parts.