Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Luminaris Color and Luminaris (colorless) qPCR Master Mixes are provided for probe or SYBR Green detection chemistries. Individual formulations with ROX or fluorescein as passive reference dyes are compatible with most qPCR platforms.
The Luminaris Color qPCR Master Mixes are specially formulated to produce consistent and reproducible qPCR data by using four levels of control over variation in your real-time PCR:
Luminaris Color qPCR Master Mixes incorporate an inert blue dye which significantly enhances the contrast between the reagent and plastic and does not affect the qPCR reaction. The Yellow Sample Buffer complements the color system by making the overall dispensing of qPCR reaction components quick and easy. This is particularly important when using opaque white reaction plates and tubes, generally recognized as giving superior qPCR results.
Figure 1. Colored solutions for easy reaction setup in white plates. Blue Luminaris Color qPCR Master Mix combined with the Yellow Sample Buffer turns the solution green and make dispensing of reaction components easy. Luminaris Master Mixes are also available in colorless formulations. The performances of Luminaris (colorless) and Luminaris Color Master Mixes are equal.
Even minute amounts of contaminating DNA can lead to false positive results in qPCR. The UDG enzyme included in Luminaris qPCR Master Mix degrades possible carry-over amplicons from previous qPCR reactions and allows amplification of specific products only.
Figure 2. UDG removes carry-over contaminations in qPCR for more accurate results. A gene was amplified from human gDNA (100 ng – 10 pg) spiked with dU-containing PCR product (3000 copies/sample). DNA was amplified with or without UDG treatment step on ABI StepOnePlus™ Real-time PCR instrument using Luminaris Color Probe High ROX qPCR Master Mix. NTC: no-template control.
Luminaris Color qPCR Master Mixes are created to provide the highly specific qPCR results. The chemically modified Hot Start Taq DNA polymerase included in the master mix has ultra low residual activity until thermally activated. This eliminates non-specific amplification and primer dimers formation during reaction setup. Reactions with Luminaris qPCR Master Mixes can be stored for up to three days after reaction setup without impacting specificity or sensitivity.
Figure 3. Exceptionally low residual activity of Hot Start Taq DNA polymerase enables unmatched stability of fully assembled qPCR reactions. Amplification of a gene from human genomic DNA (100 ng – 10 pg) with Luminaris Color HiGreen qPCR Master Mix and a master mix from other supplier. Reactions were setup and run either immediately or after 72 h on the Thermo Scientific™ PikoReal™ 96 Real-Time PCR System. Amplification curves and melting curve analysis indicate high specificity and sensitivity of reactions with Luminaris master mix. NTC - no-template control.
The high sensitivity of Luminaris qPCR Master Mixes allows accurate quantification of low-copy targets.
Figure 4. Detection of single copy target with Luminaris Color qPCR Master Mixes. A human gene was amplified in 384 replicate reactions containing an average of one copy of target DNA molecules (3.33pg of human genomic DNA) per reaction using Luminaris Color HiGreen High ROX Master Mixes on ABI Viia7™ Real-Time PCR instrument. Amplification plot (left) and normal distribution curve of Cq values (right) are shown. The obtained detection rates of at least one target copy per reaction (p=0.59 and p=0.65) are in accordance with the statistical Poisson probability distribution rate for rear events, which equals 0.631.
1. Lockey, C., et al., Real-Time Fluorescence Detection of a Single DNA Molecule, BioTechniques, 24, 744-746, 1998.
HiGreen High ROX qPCR Master Mix | HiGreen Low ROX qPCR Master Mix | HiGreen Fluorescein qPCR Master Mix | HiGreen qPCR Master Mix | ||
---|---|---|---|---|---|
Colorless | K0961, K0962, K0953, K0964 | K0971, K0972, K0973, K0974 | K0981, K0982, K0983, K0984 | K0991, K0992, K0993, K0994 | |
With blue dye | K0361, K0362, K0363, K0364 | K0371, K0372, K0373, K0374 | K0381, K0382, K0383, K0384 | K0391, K0392, K0393, K0394 | |
Thermo Scientific | PikoReal 24 Real-Time PCR System, PikoReal 96 Real-Time PCR System | ✓ | |||
Life Technologies | 7000, 7300, 7700, 7900, 7900HT, StepOne Plus™, StepOne™ | ✓ | |||
7500, 7500 Fast, ViiA™ 7, QuantStudio™ 12K | ✓ | ||||
Bio-Rad | CFX96™, CFX384™, MiniOpticon™, Opticon®, Opticon 2, Chromo4™ | ✓ | |||
MyiQ™, iQ5™, iCycler® iQ | ✓ | ✓ | |||
Stratagene | Mx4000®, Mx3005P®, Mx3000P® | ✓ | |||
Roche Diagnostics | LightCycler®480, LightCycler® 1.5, LightCycler® 2.0 | ✓ | |||
QIAGEN | Rotor-Gene™ 3000, Rotor-Gene™ 6000, Rotor-Gene Q | ✓ | |||
Eppendorf | MasterCycler® ep realplex | ✓ | |||
Cepheid | SmartCycler® SmartCycler® II | ✓ | |||
Techne | PrimeQ | ✓ | |||
Illumina | Eco Real-Time PCR System | ✓ |
Probe High ROX qPCR Master Mix | Probe Low ROX qPCR Master Mix | Probe qPCR Master Mix | ||
---|---|---|---|---|
With blue dye | K0331, K0332, K0333, K0334 | K0341, K0342, K0343, K0344 | K0351, K0352, K0353, K0354 | |
Colorless | K0931, K0932, K0933, K0934 | K0941, K0942, K0943, K0944 | K0951, K0952, K0953, K0954 | |
Thermo Scientific | PikoReal 24 Real-Time PCR System, PikoReal 96 Real-Time PCR System | ✓ | ||
Life Technologies | 7000, 7300, 7700, 7900, 7900HT, StepOne Plus™, StepOne™ | ✓ | ||
7500, 7500 Fast, ViiA™ 7, QuantStudio™ 12K | ✓ | |||
Bio-Rad | CFX96™, CFX384™, MiniOpticon™, Opticon®, Opticon 2, Chromo4™ | ✓ | ||
MyiQ™, iQ5™, iCycler® iQ | ✓ | |||
Stratagene | Mx4000®, Mx3005P®, Mx3000P® | ✓ | ||
Roche Diagnostics | LightCycler®480, LightCycler® 1.5, LightCycler® 2.0 | ✓ | ||
QIAGEN | Rotor-Gene™ 3000, Rotor-Gene™ 6000, Rotor-Gene Q | ✓ | ||
Eppendorf | MasterCycler® ep realplex | ✓ | ||
Cepheid | SmartCycler® SmartCycler® II | ✓ | ||
Techne | PrimeQ | ✓ | ||
Illumina | Eco Real-Time PCR System | ✓ |
For Research Use Only. Not for use in diagnostic procedures.