Specifications
ApprovalsUS FCC: Part 15.247; EU: ETS 300.328; License free
Audible AlarmMode: Ultra Loud Continuous Tone; Sound Pressure: 108 dBA at 15 VDC, 24 inches;
Backup Battery9.6 Volt Ni-MH, 8xSC, 3000 mAh
Cabinet MaterialWatertight, injection molded polycarbonate
ChannelsUSA: 75; France: 33; Spain: 25; Japan: 25
CurrentPower Supply: 100 mA; Strobe Light: 150 mA at 12 VDC; Sound Alarm: 30 mA at 5 VDC
DescriptionArea Monitoring Package
Channel Data Rate460 Kbps
Operating Range (English)Indoor: 450 to 900 ft.; Outdoor w/ Supplied Antenna: 3000 ft. (w/ Gain Antenna: >6 miles)
Operating Range (Metric)Indoor: 137 m to 275 m; Outdoor: 915 m with supplied
Radiation TypeGamma
Sensitivity0.5 mR/h-30R/h range
Error Correction24-bit CRC and ARQ
Frequency Band Details2400 to 2483 MHz (USA); 2448 to 2480 MHz (France)
IncludesCNET1500 NDS (with EPD); ViewPoint Enterprise Software System; CNET1500 W Wireless Network Base; EPG-G Gamma Radiation Dosimeter; Onsite support/training
Interface BoardRadio Interface; RS-232 Asynchronous
I/O Data RateUp to 230 Kbps
MaterialWatertight, injection molded polycarbonate
Modulation TypeGMSK
Network ProtocolARQ: Dynamically assigned TDMA
Network TopologyStar
Output Impedance50Ω
ProcessorCNET 1500
Receiver Sensitivity-93 dBm for 10-5 BER
Strobe Light Flash Rate115/min.
Strobe Light Operating Life200 hr.
Transmit Power Output100 mW
Product TypeArea Radiation Monitoring System for Nuclear Power Plants
Weight (English)1.75 lb.
Weight (Metric)0.79 kg
VoltagePower Supply: 9 VDC; Strobe Light: 6 - 14 VDC; Sound Alarm: 5 - 15 VDC
Unit SizeEach