Qubit™ RNA IQ Assay Kits
Qubit users may require a firmware update to use the RNA IQ Assay - Learn more »
Qubit™ RNA IQ Assay Kits
Invitrogen™

Qubit™ RNA IQ Assay Kits

Obtain ready-to-use detection of RNA degradation information with the Qubit RNA integrity and quality (IQ) Assay Kit and Standards, which feature two unique dyes for binding large and/or highly structured RNA and small, degraded RNA. Together, these dyes enable detection of RNA quality and integrity.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberAssayFor Use With (Equipment)No. of Reactions
Q33221Qubit RNA Integrity and Quality (IQ) Assay KitQubit 4 Fluorometer, Qubit Flex Fluorometer75 Assays
Q33222Qubit RNA Integrity and Quality (IQ) Assay KitQubit 4 Fluorometer, Qubit Flex Fluorometer275 Assays
Catalog number Q33221
Price (USD)
216.00
Each
Add to cart
Assay:
Qubit RNA Integrity and Quality (IQ) Assay Kit
For Use With (Equipment):
Qubit 4 Fluorometer, Qubit Flex Fluorometer
No. of Reactions:
75 Assays
Price (USD)
216.00
Each
Add to cart

Quickly and easily determine RNA degradation with the Qubit RNA IQ Assay Kit and Qubit RNA IQ Standards. RNA integrity and quality (IQ) information is assessed using the assay kit's two unique dyes: one dye that binds to large and/or highly structured RNA and a second dye that selectively binds to small, degraded RNA. Together, the dyes enable you to quickly assess the quality and integrity of your RNA samples, with results presented as an RNA IQ number and as a calculated percent of large and small RNA in the sample.

Qubit RNA Integrity and Quality (IQ) Assay Kit provides a fast, simple method to check whether an RNA sample has degraded using a Qubit 4 or Qubit Flex fluorometer. The RNA IQ assay utilizes two unique dyes: one that binds to large, intact, and/or highly structured RNA (mRNA, tRNA, rRNA), and another that selectively binds to small and/or degraded RNA. Together they enable you to quickly assess the quality and integrity of the RNA sample.

To use, simply add your samples to the RNA IQ working solution, then measure the signal on a Qubit 4 or Qubit Flex fluorometer. Results are presented as an RNA IQ number (RNA IQ#) that indicates the RNA sample integrity and quality. Results are also posted as a calculated percent of large and small RNA in the sample. The RNA IQ# is a value from 1 to 10, similar to other RNA quality scores, where a small number indicates that the sample is comprised of mainly small RNA and a larger number indicates that the sample consists of mainly large RNA or RNA with tertiary structure.

Other features of the Qubit RNA IQ Assay Kit include:
• 5S and tRNA tertiary structure binds large RNA dye
• Accuracy even in the presence of salts, protein, solvents, and RNA stabilization reagents
• Signal stable for 1 hour

Solution-based chemistry in line with electrophoresis
The RNA IQ assay results correlate well with electrophoretic methods. The primary difference between the solution-based RNA IQ assay and traditional electrophoresis-based techniques is the amount of time it takes to ascertain whether an RNA sample has degraded. Gels are considered easy to perform, but still take time. Microfluidic-based methods not only take time to obtain results, but often have lengthy procedures to prepare the samples. Gel or microfluidic-based electrophoresis is still recommended for obtaining fragment size information or size distribution of the RNA sample.

Qubit RNA IQ Assay Standards
Qubit RNA IQ Assay RNA standards are designed for use with the Qubit RNA IQ Assay Kit. Sufficient amounts of the small and large and/or structured RNA standard are supplied for generating an IQ standard curve for up to 500 samples. The RNA IQ standards are designed to measure RNA degradation and are not interchangeable with the standards from other RNA quantitation assays, including the Qubit RNA HS, BR, or XR assay kits.

Notes
• Qubit RNA IQ assay kits are designed to work on Qubit 4 and Qubit Flex fluorometers
• The assay is not designed for use with Qubit, Qubit 2.0, or Qubit 3 fluorometers
• Use thin-wall, clear, 0.5 mL PCR tubes (Cat. No. Q32856) for the Qubit 4 Fluorometer and 8 x 200 μL tube strips (Cat. No. Q33252) for the Qubit Flex Fluorometer

For Research Use Only. Not for use in diagnostic procedures.
Specifications
AssayQubit RNA Integrity and Quality (IQ) Assay Kit
FormatKit
Sample TypeRNA
For Use With (Equipment)Qubit 4 Fluorometer, Qubit Flex Fluorometer
No. of Reactions75 Assays
Product LineQubit
Shipping ConditionDry Ice
Unit SizeEach

Frequently asked questions (FAQs)

Can the Qubit RNA IQ Assay Kits (Cat. No. Q33221, Q33222) be run on a plate reader for high throughput screening of RNA integrity?

Qubit RNA IQ Assay Kits are not compatible with plate readers. The IQ value calculations are performed by the Qubit instrument, which involves proprietary algorithms that cannot be replicated on other devices. For accurate results, use the Qubit instrument as recommended.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I am using the Qubit RNA IQ Assay Kit (Cat. No. Q33221, Q33222). How do I convert the RNA IQ score to the RIN score?

There is no simple way to convert the RNA IQ score to RIN, because they measure different things. The application note, Qubit RNA IQ Assay: a fast and easy fluorometric RNA quality assessment, shows a detailed comparison and explanation of the two measurements. Figures 2 and 4 are most relevant.

Does the Qubit RNA IQ Assay detect free nucleotides/bases?

No. The presence of an excess amount of free nucleotides/bases may affect the assay results in the same manner as other contaminants, but the reagents in this kit do not give a fluorescence response to nucleotides or bases.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Do you offer a Qubit assay to detect purity of the RNA or DNA samples (level of protein contamination)?

At present, we do not have a fluorescence-based assay that tests for sample purity (protein contamination). We do offer various instruments that can obtain absorbance readings (absorbance at 260/280), such as our NanoDrop, BioMate and GENESYS spectrophotometers.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Does the Qubit RNA IQ Assay detect the purity of the RNA sample, similar to using the 260/280 absorbance method?

No. The Qubit RNA IQ Assay does not assay the purity of the RNA sample, only the extent of degradation of the RNA (small versus large strands).

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.