The Ambion™ NorthernMax™ Kit contains a complete set of RNase-free reagents for running formaldehyde-based northern analysis. This kit is ideal for the investigator who wants to use familiar reagents while taking advantage of NorthernMax™ Kit's high sensitivity. Sufficient reagents are provided to process 1000 cm2 membrane.

• Increase sensitivity up to 100x over standard hybridization protocols
• Reduce hybridization to just 2 hours for many messages
• Complete kit contains ULTRAhyb™ Hybridization Buffer and gel and wash reagents for 10–20 gels
• Compatible with RNA, DNA, or oligonucleotide probes; labeled isotopically or nonisotopically

The included ULTRAhyb™ Ultrasensitive Hybridization Solution increases the sensitivity of RNA probes up to 20x and DNA probes up to 100x. Hybridization can be completed in just 2 hours for many messages. The NorthernMax™ Kit is compatible with DNA, RNA, or oligo probes labeled isotopically or nonisotopically. The NorthernMax™ Kit contains everything you need to conduct northerns. Positively charged nylon membranes must be purchased separately (see Accessory Products). An RNA sample and template for probe synthesis are also provided as controls for each kit.

Accessory Products:
The BrightStar™ -Plus Positively Charged Nylon Membranes (SKU# AM10100, AM10102, or AM10104) are optimized for use with the NorthernMax™ Kit.
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov
For Research Use Only. Not for use in diagnostic procedures.
Specifications
Product TypeNorthern Analysis Reagents
Gel CompatibilityFormaldehyde-Containing Gels
Quantity1 kit
Shipping ConditionRoom Temperature
Unit SizeEach
Contents & Storage
• Positive Control RNA, pTRI-GAPDH Mouse, DECAtemplate §-actin-Mouse, and Formaldehyde Load Dye should all be stored at -20°C.
• ULTRAhyb™ Buffer, 10X Denaturing Gel Buffer, and 10X MOPS Gel Running Buffer should be stored at 4°C.
• Agarose-LE™, Transfer Buffer, Low Stringency Wash Solution #1, High Stringency Wash Solution #2, and RNaseZap™ should be stored at room temperature.
• Nuclease-free water may be stored at any temperature.

Frequently asked questions (FAQs)

How can I ensure that all of an RNA sample transfers from gel to membrane?

Incomplete transfer is often caused by short-circuiting. Strips of Parafilm sealing film around the outside edges of the gel can prevent this. Large RNA species may not transfer well because of their size. A basic transfer buffer (e.g., NorthernMax One-Hour Transfer Buffer) will partially shear the RNA so that larger RNA species transfer more efficiently. Check RNA transfer by including ethidium bromide in RNA samples or staining the gel in ethidium bromide after transfer and viewing your gel under UV light. RNA markers are invaluable to demonstrate whether large RNAs have fully transferred. Our Invitrogen Millennium Markers are especially useful for this purpose, since they include transcripts at 1,000 nt intervals from 0.5 to 9 kb.

How can I prevent cross-hybridization to rRNA sequences?

rRNA makes up ~80% of total RNA samples. When 10 µg of total RNA is loaded into a Northern gel lane, the 18S and 28S rRNA bands contain 2-6 µg RNA each. This amount of nucleic acid can nonspecifically trap probe as well as bind complementary sequence. Probe trapping by rRNA can be reduced by using the minimal amount of probe, and by labeling only sequence complementary to mRNA. Transfer using a basic buffer can prevent trapping. Finally, you can use a high hybridization and wash temperature to minimize cross hybridization to rRNA.

Can I reprobe my Northern blot? Do you offer stripping recommendations?

For RNA probes on DNA or RNA targets:
Autoclave the membrane in a bottle containing 0.1% SDS solution for 15 minutes. Repeat if necessary.

For DNA probes on DNA targets only:
You can use the same protocol used for RNA probe stripping.

Another option is alkaline denaturation. Incubate the membrane with 400 mM NaOH for 30 minutes, then wash with 0.1% SDS for 15 minutes. These stripping methods should work for 2 to 3 stripping procedures. However, nucleic acids will gradually be removed from the blot.

How can I increase the sensitivity of my Northern hybridizations?

Please see below the top ten ways to increase sensitivity of your Northern hybridizations:

1) Increase the amount of RNA loaded in each lane (up to 30 mg).
2) Use poly(A) RNA instead of total RNA; 10 mg of poly(A) RNA is ~300-350 mg total RNA (3-5%).
3) Switch to ULTRAhyb Ultrasensitive Hybridization Buffer.
4) Switch from DNA to RNA probes.
5) Use downward alkaline capillary transfer.
6) Use an optimal hybridization temperature.
7) Use a freshly synthesized probe.
8) Use a high specific activity probe (10^8 to 10^9 cpm/mg).
9) Increase exposure time (it can take up to 3 days to see low-abundance messages with radiolabeled probes).
10) Follow the manufacturer's recommendations to crosslink the RNA to the membrane.

Read more about these suggestions here (https://www.thermofisher.com/us/en/home/references/Invitrogen-tech-support/northern-analysis/general-articles/ten-ways-to-increase-the-sensitivity-of-northern-hybridizations.html).

Is it possible to make the Northern blotting procedure faster?

Running small 10 cm gels for Northern blotting takes 30-90 minutes, much quicker than larger gels. The biggest time savings, however, can be during transfer to the membrane. Traditionally, Northerns have been blotted overnight using capillary transfer and a high-salt buffer (10X SSC or 10X SSPE). By using a weak base as the medium (e.g., NorthernMax One-Hour Transfer Buffer), the transfer can be completed in just 1 hour. Alternatively, you can electroblot your RNA in 1 hour.