Arcturus Cellect Laser Capture Microdissection System
Attention: Thermo Fisher Scientific has signed an Agreement with Laxco Inc. to commercialize the Arcturus Cellect LCM system. Effective immediately, Laxco will be responsible for the commercialization of the new Cellect LCM systems globally. If you need a quote or require more information, please visit https://www.laxcoinc.com/lcm or contact: AccuvaCellect@laxcoinc.com. The official customer communication can be found here.
Arcturus Cellect Laser Capture Microdissection System
Actual product may vary
Arcturus Cellect Laser Capture Microdissection System
Arcturus Cellect Laser Capture Microdissection System
Thermo Scientific™

Arcturus Cellect Laser Capture Microdissection System

The Arcturus Cellect is a dual laser microdissection capture platform to harvest cells of interest for DNA/RNA and protein research. The Arcturus Cellect platform is designed to be precise and contact-free to help minimize contamination concerns. The Cellect supports all consumables and reagents used by Arcturus legacy instruments.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberDescriptionImage CompatabilityLight SourceCamera
A40330Arcturus Cellect Laser Capture Microdisection System - BrightFieldColor camera with a 1.67 um X 1.67 um pixel sizeLED brightfield with phase capability10 MP
A40328Brightfield with Large MonitorColor camera with a 1.67 um X 1.67 um pixel size LED brightfield with phase capability 10 MP
A40329Arcturus Cellect Laser Capture Microdissection System - Fluorescence with Large MonitorColor camera with a 1.67 um X 1.67 um pixel size. Monochrome camera with 6.45 um X 6.45 um pixel size – Used as a dedicated camera for fluorescence researchLED brightfield with phase capability. Fluorescence with three channel capability in the following excitations and emissions:

  • 480/30X excitation  535/40M emission
  • 560/40X excitation  636/60M emission
  • 375/28X excitation  460/50M emission
10 Megapixel color camera. 1.4 Megapixel monochrome camera – Used as a dedicated camera for fluorescence research
A40331Arcturus Cellect Laser Capture Microdisection System - FluorescenceColor camera with a 1.67 um X 1.67 um pixel size. Monochrome camera with 6.45 um X 6.45 um pixel size – Used as a dedicated camera for fluorescence researchLED brightfield with phase capability. Fluorescence with three channel capability in the following excitations and emissions:

  • 480/30X excitation  535/40M emission
  • 560/40X excitation  636/60M emission
  • 375/28X excitation  460/50M emission

10 Megapixel color camera. 1.4 Megapixel monochrome camera – Used as a dedicated camera for fluorescence research
Catalog number A40330
Price (USD)
-
Description:
Arcturus Cellect Laser Capture Microdisection System - BrightField
Image Compatability:
Color camera with a 1.67 um X 1.67 um pixel size
Light Source:
LED brightfield with phase capability
Camera:
10 MP
The Arcturus Cellect is a dual laser microdissection capture platform to harvest cells of interest for DNA/RNA and protein research. The Arcturus Cellect platform is designed to be precise and contact-free to help minimize contamination concerns. The Cellect supports all consumables and reagents used by Arcturus legacy instruments. The Arcturus Cellect offers an IR laser and UV laser capability for cell harvesting. The Arcturus Cellect's IR laser is capable of cell harvesting with no damage to the cell's nucleic acid or any degradation to the RNA. Arcturus Cellect UV laser provides the ability to cut through dense tissue as well as the capability of cutting through bone.
The Arcturus Cellect is a dual laser microdissection platform used by researchers to harvest cells of interest for DNA, RNA, and protein research.  The Arcturus Cellect offers an IR laser and UV laser capability for cell harvesting.  The Arcturus Cellect's IR laser is capable of cell harvesting with no damage to the cell's nucleic acid or any degradation to the RNA.  The IR laser also offers single cell capture of cells as small as 10 um in diameter.  The Arcturus Cellect UV laser provides the ability to cut through dense tissue as well as the capability of cutting through bone.  The Arcturus Cellect laser capture microdissection platform is designed to be precise and contact-free to help minimize contamination concerns.  Cap movement is performed by an automated system which reduces human interaction of the CapSure caps which minimizes potential contamination during cell harvesting.

During cell harvesting, the cells to be harvested are marked-up in the software and remains marked throughout the session in order to verify cell locations.  The software also calculates the total amount of cells harvested on each CapSure cap.  This information as well as any additional notes about the tissue slide and the CapSure cap can be saved by the researcher .  A visual inspection of the cells harvested can be performed by placing the CapSure cap in the QC position on the Cellect stage.  Images of the tissue before cell harvesting, post cell harvesting, and the cells harvested on the CapSure cap can be saved for documentation purposes.  This process provides sample custody and is proof of the cells harvested for downstream analysis.
 
The Cellect was designed to support proven Arcturus LCM workflows used by Arcturus legacy instruments such as the ArcturusXT and Veritas.  The Cellect also supports all consumables and reagents used by Arcturus legacy instruments.  Researchers can work with formalin-fixed paraffin-embedded (FFPE) tissue, frozen tissue, and live cells for their experiments on the Arcturus Cellect.    
 
The Arcturus Cellect offers:
 
  • 808 nm IR and 355 nm UV lasers – Used for cell harvesting
  • LED brightfield with phase capability – Used to view cell morphology
  • 2X, 4X, 10X, 20X, 40X, and 60X objectives standard – Used to view cells as different magnifications
  • 10 Megapixel color camera with a 1.67 um X 1.67 um pixel size – Provides sharp resolution for detailed picture quality 
  • Fully automated stage with 1 um precision – Provides repeatability of movement when harvesting cells
  • 3 stage inserts for personalized research – 3 slide stage insert that hold traditional slide size of 75 mm x 26 mm, 2 large format slide stage insert that holds slide size of 75 mm x 50 mm, and a petri dish stage insert that holds a 50 mm x 7 mm petri dish
  • Fully automated CapSure™ cap movement system – Provides hands-free capability when moving Arcturus™ Capsure™ caps during research to minimize contamination
  • Onboard Intel™ NUC™ PC with Microsoft™ Windows™ 10 OS – Provides powerful integrated PC to operate instrument software and monitor interface
  • 32 in. WACOM ultra HD touchscreen monitor option – Possesses ultra-sensitive screen with 8192 sensitivity levels for marking up cell harvesting areas, 5080 LPI resolution, and 1.07 billion display colors (10 bits color)
  • Complete line of consumables and reagents - Used to support LCM DNA, RNA, and protein research
  • Complete LCM Workflows – Protocols designed to be used for LCM research 
Specifications
Camera10 MP
DescriptionArcturus Cellect Laser Capture Microdisection System - BrightField
For Use With (Equipment)The Cellect also supports all consumables and reagents used by Arcturus legacy instruments.
Detection MethodVisual detection through imaging
Image CompatabilityColor camera with a 1.67 um X 1.67 um pixel size
Light SourceLED brightfield with phase capability
Magnification2X, 4X, 10X, 20X, 40X, and 60X objectives standard
Objectives2X, 4X, 10X, 20X, 40X, and 60X objectives standard
Unit SizeEach 1