MagMAX™ FFPE DNA/RNA Ultra Kit
Inquire about OEM or Commercial Supply version of this product here.
MagMAX™ FFPE DNA/RNA Ultra Kit
Applied Biosystems™

MagMAX™ FFPE DNA/RNA Ultra Kit

The MagMAX™ FFPE DNA/RNA Ultra Kit is designed for sequential isolation of DNA and RNA from the same formaldehyde- orRead more
Have Questions?
Catalog number A31881
Price (USD)
820.00
Each
Add to cart
Price (USD)
820.00
Each
Add to cart
The MagMAX™ FFPE DNA/RNA Ultra Kit is designed for sequential isolation of DNA and RNA from the same formaldehyde- or paraformaldehyde-fixed paraffin-embedded (FFPE) tissue sample. The DNA and RNA are recovered in separate eluates, and both are compatible with a broad range of applications, including real-time PCR and next-generation sequencing. The isolation of RNA and DNA from the same FFPE sample makes this kit an ideal method of sample preparation for Oncomine™ Comprehensive and Oncomine™ Focus assays.

Features of the MagMAX FFPE DNA/RNA Ultra Kit include:
• Flexible design that permits both manual and automated isolation of RNA and DNA
• Minimal requirement of 5 μm section or curl input
• Capable of processing 40 μm FFPE sections or curls; greater than 40 μm sections can be processed with an alternative protocol
• Compatible with targeted RNA and DNA sequencing panels
• Contains Dynabeads™ MyOne™ Silane for consistent isolation of RNA, microRNA, and DNA
• Alternative protocols for the isolation of RNA or DNA only

Unlocking the information contained in FFPE samples is essential to cancer research. Common nucleic acid isolation methods require you to choose which nucleic acid to recover from a given sample, with loss of the other nucleic acid (and any information that may have resulted from its analysis). Alternatively, the DNA and RNA are co-purified, or the sample is split in half so that each can be purified.

More information from less sample input
The MagMAX FFPE DNA/RNA Ultra Kit protocol addresses these issues by first isolating DNA from the FFPE sample and then recovering the RNA from the DNA-depleted supernatant. The nucleic acids are prepared as separate eluates and are then ready for downstream analysis. This allows for a fuller analysis of precious samples, including investigation of important biomarkers, such as hotspot mutations, CNVs, gene fusions, and indels.

Benefits of MagMAX magnetic bead–based purification
The magnetic bead–based purification format of the kit allows for easy scaling of the number of samples processed either manually with a magnetic stand or with a magnetic particle processor such as the KingFisher™ Duo Prime or KingFisher™ Flex processor.

Magnetic beads offer many benefits compared to other technologies for isolating nucleic acids. Beads bind the RNA and DNA more efficiently than glass fiber filters, resulting in higher and more consistent yields. Additionally, because filters and vacuum manifolds are not used, there is no risk of undigested tissue particulates clogging these items during the extraction process. This clogging issue is of particular concern with fibrous FFPE tissue samples that that are not fully digested during the proteinase K treatment.

Optimized bead surface chemistry
The Dynabeads MyOne Silane utilized in the MagMAX FFPE DNA/RNA Ultra Kit have an optimized silica-like surface chemistry with high specific surface area that allows efficient kinetics and high sensitivity in nucleic acid capture. These aspects make Dynabeads MyOne Silane ideal for the recovery of both RNA and DNA targets found in FFPE samples. Once captured, both of these nucleic acids are then eluted separately in volumes of 50 μL and are ready for downstream applications.

For Research Use Only. Not for use in diagnostic procedures.
Specifications
FormatKit
Isolation TechnologyMagnetic Bead
Sample TypeFFPE, Fixed Samples
For Use With (Application)Next-Generation Sequencing, RT-PCR (Endpoint), Real-Time PCR, PCR, microRNA Analysis
High-throughput CompatibilityHigh Throughput Compatibility
Product LineMagMAX™
Product TypeFFPE DNA/RNA Ultra Kit
Quantity1 kit
Shipping ConditionApproved for shipment at Room Temperature or on Wet or Dry Ice
TargetTotal RNA, miRNA, Total Nucleic Acids, Genomic DNA, mRNA, Transcriptome RNA
Unit SizeEach
Contents & Storage
• 1 x 385 μL Protease, Store at -5 to -30°C
• 1 x 10 mL Protease Digestion Buffer, Store at Room Temperature
• 1 x 38.5 mL Binding Solution, Store at Room Temperature
• 1 x 1.95 mL Nucleic Acid Binding Beads, Store at 2°C to 8°C
• 1 x 38.5 mL DNA Wash Buffer, Store at Room Temperature
• 1 x 210 mL Wash Solution 2 Concentrate, Store at Room Temperature
• 1 x 5 mL Elution Solution, Store at Room Temperature
• 1 x 115 mL RNA Wash Buffer Concentrate, Store at Room Temperature
• 1 x 1.92 mL DNase, Store at -5 to -30°C
• 1 x 960 μL DNase Buffer, Store at -5 to -30°C

Frequently asked questions (FAQs)

How can I increase my chances of successful extraction of FFPE samples in terms of DNA quality and yield?

There are a number of factors that can impact the overall quality and yield of DNA isolated from FFPE tissues. Here are recommendations to address several key factors:

- Upstream tissue procurement and tissue specimen preparation - if possible, tissues should be fixed within one hour of surgical resection. The optimal fixation time is 12-24 hours using neutral-buffered formalin or paraformaldehyde. Fixed tissues should be thoroughly dehydrated prior to the embedding process.
- Block storage - storage of blocks without cut faces, when possible, prevents ongoing damage from exposure to atmospheric oxygen, water, and other environmental factors such as light and infestation (fungi, insects, etc.).
- Tissue type, size, and amount being used for DNA isolation - the recommended tissue thickness is 10-20 µm. The number of sections used is determined by the tissue type (which impacts cell density) and surface area (recommended size: 50-300 mm^2). Excess starting material can cause filter clogging, resulting in poor yield.
- Excessive amount of paraffin used for embedding tissues - when possible, excess paraffin should be trimmed away prior to starting the purification protocol. For xylene-based purification methods, two xylene treatments at room temperature should be sufficient for complete deparaffinization. If desired, a more rigorous 37-55 degrees C treatment can be performed for up to 30 minutes. After the xylene deparaffinization, it is crucial that the 100% ethanol is completely removed and the pellets are dry after the two 100% ethanol washes. The magnetic bead method employs novel chemistries to deal with the paraffin that limits input to 20 µm sections.

Read more about extraction of nucleic acids from FFPE samples here (http://www.thermofisher.com/us/en/home/references/Invitrogen-tech-support/rna-isolation/general-articles/extraction-of-nucleic-acids-from-ffpe-samples.html).

What can I use to extract DNA from FFPE (formalin fixed paraffin embedded) samples?

We offer 2 kits: RecoverAll Total Nucleic Acid Isolation Kit for FFPE and MagMAX FFPE DNA/RNA Ultra Kit Read more about the differences between these kits here (http://www.thermofisher.com/us/en/home/life-science/dna-rna-purification-analysis/dna-extraction/genomic-dna-extraction/dna-extractions-working-with-ffpe-samples.html).

Is there a limit to the size of curls that can be processed with the MagMAX FFPE DNA/RNA Ultra Kit (Cat. No. A31881)?

There is no specific upper limit to curl size for use with the MagMAX FFPE DNA/RNA Ultra kit (Cat. No. A31881). If all of the tissue is able to be submerged in the 200 µL of buffer, then the large volume of protocol should work. Please keep in mind when processing sections that are thicker than 40 µm, additional digestion buffer, binding solution, and wash buffer, may need to be purchased separately (Cat. No. A32796).

Can I use a heat block for the AutoLys M tube incubation?

No. The AutoLys M tubes don't fit in a standard 1.5 mL or 2.0 mL heat block. We recommend incubating the tubes in the tube racks in an incubator or oven.

What kind of centrifuge do I need to spin down the AutoLys M Tubes (Cat. No. A38738)?

Any centrifuge with plate adapters will work. The AutoLys M Tube Racks fit nicely into those adapters.