Quantifiler™ Trio DNA Quantification Kit
Quantifiler™ Trio DNA Quantification Kit
Applied Biosystems™

Quantifiler™ Trio DNA Quantification Kit

The Quantifiler Trio DNA Quantification Kit is a robust kit that enables forensic laboratories to simultaneously obtain a quantitative andRead more
Have Questions?
Catalog number 4482910
Price (USD)
2,565.00
Each
Add to cart
Price (USD)
2,565.00
Each
Add to cart
The Quantifiler Trio DNA Quantification Kit is a robust kit that enables forensic laboratories to simultaneously obtain a quantitative and qualitative assessment of total human and human male DNA in a single, highly sensitive real-time PCR reaction. This guides selection of the optimal short tandem repeat (STR) analysis chemistry (autosomal, Y-STR, or miniSTR) and streamlines the workflow while increasing downstream analysis success rates. The kit includes enhanced quantity and quality indicators that help deliver accurate, sensitive, and specific results that work together with the HID Real Time PCR Analysis Software v1.2 to enable informative and integrated workflow decisions. The Quantifiler Trio kit and the HID v1.2 software are designed for use with the Applied Biosystems 7500 Real-Time PCR System.

Highly Accurate
• Determines the ratio of human male to female DNA, even with minute male and excess female DNA (1:4000 or greater)

Highly Sensitive
• <1 pg/μL limit of detection. Quantifies DNA concentrations from 0.005 ng/uL to >50 ng/uL, enabling the use of a broad range of concentrations, with flexible protocols for higher concentration samples.

Highly Specific
• Detects human and higher primate DNA

Highly Informative
• Quantifies DNA from a wide variety of sources, including buccal swabs, blood, semen, tissue, and other human DNA sources, making this kit suitable for casework sample screening, databasing, and paternity labs
• Guides selection of the optimal AmpFLSTR PCR Amplification Kit (autosomal, Y-STR, or miniSTR)
• Quality Index helps improve prediction of STR amplification performance and estimation of DNA quantity in degraded samples, especially in the presence of inhibitors.
• Enhanced inhibition detects the presence of PCR inhibitors (suggesting additional purification of extract and/or whether a mini STR kit like the MiniFiler, NGM SElect, or GlobalFiler kit may be necessary).

Highly Reliable
• Uses gold standard TaqMan real-time PCR technology already widely adopted in forensic laboratories. Real-time PCR has the widest dynamic range of any DNA detection technology, allowing for more accurate quantification of low level samples.

Highly Efficient
• Dual quantification system minimizes sample consumption and streamlines workflow, with results in ∼1 hour.
• Optimized and validated as part of a complete DNA testing system with the Applied Biosystems 7500 Real-Time PCR System, AmpFLSTR PCR Amplification kits, and HID Real Time PCR Analysis Software v 1.2 to enable high quality STR profiling results.

A Highly Informative Workflow Tool
The Quantifiler Trio DNA Quantification Kit has been optimized and validated as part of a complete DNA testing system with the AmpFLSTR PCR Amplification kits. The chemistry is compatible with commonly used extraction technologies for easy integration into current lab workflows. This enables the Quantifiler Trio kit to function as a critical component of an improved and integrated workflow for more effective processing of forensic casework samples. Both the kit and the software are fully automatable with most liquid handling robotic platforms.

Comparison to Quantifiler Duo Kits
There are several specific differences between the Quantifiler Trio DNA Quantification Kit and the Quantifiler Duo DNA Quantification Kit, including:
Target Loci: The Quantifiler Trio kit uses multiple-copy target loci for improved detection sensitivity. There are three human-specific target loci: Small Autosomal, Large Autosomal, and a Y-chromosome target. Each consists of multiple copies dispersed on various autosomal chromosomes (Small Autosomal and Large Autosomal) or multiple copies on the Y-chromosome.
Optimized Chemistry: The assay chemistry has been optimized for more efficient multiplexing, faster PCR cycle times (∼1 hour), and better inhibitor tolerance. The overall performance improvements allow the Quantifiler Trio kit to better match the enhanced performance of newer STR kits that are designed to accommodate more challenging samples, like the Identifiler Plus, NGM SElect, or GlobalFiler PCR Amplification kits.
DNA Standard: The Quantifiler Trio DNA Standard is a pooled, human genomic, smaller molecular weight DNA for improved stability, homogeneity, and correlation with forensic samples. There is a five point standard curve protocol that helps improve efficiency with up to 6% more samples on a plate.
Packaging Features: To help laboratories control for and minimize the potential of reagent contamination, as well as to better accommodate automated platforms, the Quantifiler Trio DNA Quantification Kit has some key packaging features:
    --Four 100-reaction individual-use screw cap tubes (1 tube will process a 96 well plate)
    --The DNA standard is packaged in a separate box.
    --Both the reagent and DNA standard box are shipped together in an STR-style sleeve with peel & stick reagent lot barcode labels. This allows customers to separate out the reagents easily for special storage upon arrival at the laboratory.
Specifications
Product LineQuantifiler
Quantity400 reactions
TargetLarge autosomal (LA) human target, Y chromosome, small autosomal (SA) human target
Unit SizeEach
Contents & Storage
Store at -5°C to -30°C upon receipt, 2°C to 8°C after initial use.

Frequently asked questions (FAQs)

How does the quantification solution provided by the Quantifiler Trio and HP DNA Quantification Kits and HID Real-Time PCR Software easily integrate with robotics for an automated workflow?

Robotic integration is enabled by the automation-friendly bundling of the Quantifiler Trio and HP DNA Quantification kits combined with the HID Real-Time PCR Analysis Software, which has been designed to facilitate automation with commonly used robotic platforms. In addition, our Human Identification Professional Services (HPS) team has extensive expertise in developing customized robotic scripts and conducting on-site verification and validation testing to help you achieve optimal performance with a wide range of platforms. The HPS team has already developed scripts for the Quantifiler Trio and HP DNA Quantification kits on several of the most common robotic platforms, and would be happy to consult with your lab on how to efficiently implement these solutions into your workflow. Please contact your local human identification (HID) account manager to learn more.

Can I use the basic SDS v1.2.3 software to analyze data generated with the Quantifiler Trio and HP DNA Quantification kits?

We do not recommend using the basic SDS v1.2.3 software. The Quantifiler Trio and HP DNA Quantification kits were developed and validated using the HID Real-Time PCR Software. The software ensures the optimal performance of new Quantifiler Trio and HP DNA Quantification kit-specific functionality, such as the automatic calculation of M:F ratios, Degradation Index and streamlined setup for the latest STR analysis kits including the Identifiler Plus, NGM Select and GlobalFiler kits.

What instrument can I use with the Quantifiler Trio and HP DNA Quantification kits and HID Real-Time PCR Software quantification solution?

The Quantifiler Trio and HP DNA Quantification kits and HID Real-Time PCR Analysis Software v1.3 have been validated to perform on the Applied Biosystems 7500 Real-Time PCR System.*

HID Real-Time PCR Analysis Software v1.4 has been validated to perform on the Applied Biosystems QuantSudio 5 and 7500 Real-Time PCR Systems.

* When used for purposes other than human identification, the instruments cited are for Research Use Only. Not for use in diagnostic procedures.

Does the Quantifiler Trio DNA Quantification Kit assay perform well with male:female mixture samples?

We evaluated male:female DNA ratios up to 1:4,000 with 20 pg/µL male DNA and were able to accurately quantify the male and female DNA fractions. For more detailed information, you can refer to the Mixture Study in the Quantifiler HP and Trio DNA Quantification Kits user guide.

How is female DNA detected with the Quantifiler Trio and HP DNA Quantification kits? Is there a specific marker for females?

By subtracting the male DNA concentration from the human DNA concentration, the concentration of female DNA can be approximated.